How to Compare BOM Revisions Without Mistaking Renumbered Rows for Quantity Changes
The new BOM has different item numbers. Before you chase a quantity change, check whether the component line actually changed or simply moved in the numbering.
A row-by-row comparison can pair the wrong parts after a revision. Matching only the part code can also combine the same component used under different parents or configurations. This synthetic workbook compares supplied stable line IDs and keeps the surrounding scope beside each result.
Download the BOM revision comparison workbook. Every record is invented for this example.
The reported problem
In a 2017 Italian CAD3D discussion, an automation designer describes exporting a structured BOM to CSV for an ERP system. The first import works, but comparing later exports by item number breaks when a component receives a different number. A reply separates part identification from parent-child assembly relationships.
A January 2026 myCAD discussion asks about reading item references and quantities from a drawing BOM. Replies explain how to read the table and caution that configurations and subassemblies can affect quantities. These are reported workflow problems, not defects reproduced by this workbook.
Autodesk’s Inventor BOM reference documents renumbering based on sort order and distinguishes a structured BOM from a flat parts-only view. It also describes part-number row merging. Keep export settings consistent before treating the two tables as comparable.
Use a stable identity before comparing quantities
The example supplies stable line IDs L1 through L5 across revisions. These are example evidence, not a promise that a CAD export automatically contains a suitable ID. A real workflow needs a stable identifier or an approved, unique crosswalk. Display item numbers and spreadsheet row positions are not used as matching keys here.
The source tables are Exports!A10:G13 for R1 and Exports!A19:G22 for R2. Revision labels are in B4:B5. Both coverage confirmations, C4:C5, are Yes. The scope in B6 is one top assembly with all lines included and local quantity per parent.
For a matched line, parent path, part code, configuration and unit must all be present and agree before the workbook calculates a quantity change. A stable ID with a changed configuration or parent goes to review. That prevents a technically matched ID from hiding a different comparison.
The independently calculated result
| Stable ID and scope | R1 to R2 | Decision and original cells |
|---|---|---|
| L1: P7, Machine/Frame, configuration A, ea | Quantity 2 to 3. Item 10 to 15. | Quantity increased by 1 ea and item was renumbered. Exports!A10:G10 and A20:G20. |
| L2: P7, Machine/Motor, configuration B, ea | Quantity 1 to 1. Item 20 to 5. | Renumbered only. Exports!A11:G11 and A19:G19. |
| L3: P8, Machine/Cover, configuration A, ea | Quantity 4 to absent. | Removed from the confirmed complete R2 scope. Local change minus 4 ea. Exports!A12:G12; no L3 in A19:A22. |
| L4: P9, Machine/Base, configuration A, ea | Quantity 2 to 2. Item 40 to 25. | Renumbered only. Exports!A13:G13 and A21:G21. |
| L5: P10, Machine/Guard, configuration A, ea | Absent to quantity 1. | Added to R2. Local change plus 1 ea. Exports!A22:G22; no L5 in A10:A13. |
There is one matched line with a quantity change, two lines that were only renumbered, one removed line and one added line. L1 also has a new display item, but it belongs in the quantity-changed category rather than renumbered only.
P7 appears under two different parents and configurations. Its Frame/A line changed; its Motor/B line did not. Keep that distinction visible instead of presenting a part-code-only difference as if it explained where the change occurred.
Compare both directions
The Comparison sheet checks every R1 line, then checks R2 for IDs missing from R1. This includes both removed and added lines. R2 candidates already handled by an R1 row stay blank so they are not counted twice.
The summary counts quantity-changed lines in Comparison!D4, added lines in D5, removed lines in D6, and renumbered-only lines in I4. Review rows are in I5; comparison completeness is in I6.
The formulas check uniqueness before retrieving a quantity. A blank quantity stays unavailable, while a genuine numeric zero stays zero. Duplicate or missing IDs, invalid quantities, missing scope fields and incompatible matched scopes remain visible for review.
An absent row needs coverage evidence
A component missing from a filtered export is not enough to prove removal. Change either coverage confirmation to No and the example withholds added/removed classifications, marks those candidates for coverage review and shows the complete comparison as pending. Matched records can still provide known comparisons, but the source pair no longer supports a complete change list.
The confirmations are manual evidence declarations. The workbook cannot establish that an unseen CAD model or export is complete. Check the same top assembly, BOM view, configuration/model state, suppression choices, units and revision scope before confirming coverage.
Use the local change for the right question
This example compares local quantities per parent. It does not multiply through assembly levels, calculate procurement demand or change inventory. Do not sum the deltas of unrelated parts into a single material quantity. If you need a total requirement, build a separate calculation with parent multiplicities and the correct unit rules.
The workbook contains four rows per export. For a larger comparison, extend both source ranges and all comparison candidates together. Excel’s familiar matching and counting functions treat text keys without case sensitivity; use a canonical ID policy first if your source distinguishes IDs by letter case.
What was tested in Jolene
Tested November 24, 2026. An independent record-based calculation checked the expected result. The workbook passed 1,520 assertions across 40 states, including missing and duplicate IDs, zero and invalid quantities, scope mismatches, incomplete exports, missing item numbers and reordered rows. The final original inputs and headline results were also checked in the saved XLSX.
In a separate public-file test, Jolene downloaded the exact example, reported 11,368 bytes and SHA-256 31938dd37b79a070ef008135c7cb918ebd30ec6b6fbc6de7980a7c9c9adc6f3f, and reconstructed the result from the original Exports cells without using the cached Comparison outputs. Its source rows and classifications matched the independent answer.
The native upload reached ready with six extracted tables. After selecting the uploaded file through Jolene’s file picker, a native-only test reconstructed the same line results from the original export rows and retained metadata, without using the derived comparison tables. The cited original export-row coordinates and values matched the saved workbook, as did the revision and coverage confirmations.
One native citation limit remains: the scope/rule text was retained, but its original worksheet cell address was not. The native test therefore supports the line-level reconstruction and its stated scope, with exact row citations for the exports; it does not establish exact-cell traceability for every note.
To try the check on your own workbook in Jolene.pro, select the file with @ and ask: Which stable BOM lines changed local quantity, which were only renumbered, and which are added or removed? Keep parent, configuration, unit and the original source rows beside each answer.